COMPARATIVE ANALYSIS OF AN ACTIVE POWER FLOW CONTROL FOR ADVANCED VOLTAGE SUPPORT IN GRID CONNECTED CONVERTER
Supporting The Grid And Improving Its Reliability Have Recently Become Major Requirements For Large Distributed Generation Units. Under Most Grid Faults, The Accuracy Of The Traditional Voltage Support Schemes (VSSs) Is Dramatically Affecte...
ENHANCEMENT OF SHUNT ACTIVE POWER FILTERS BY HARMONIC DETECTION SCHEMES
In This Strategy, The DC Link Voltage Is Regulated By A Hybrid Control Technique Mixed With A Standard PI And A Sliding Mode (SM) Control In Shunt Active Power Filters (SAPF). Sliding Mode(SM) Control Strategy And Feedback Linearization Bas...
COMPARISION OF THREE AND TWO LEVEL HYSTERESIS CURRENT CONTROLLER BASED ON ACTIVE POWER FILTER FOR HARMONIC COMPENSATION
This Paper Depicts The Performance Of A Three-level Hysteresis Current-control (HCC) Scheme For Three-phase Four-switch Shunt Active Power Filters. This Four-switch Topology Develops Four Power Semiconductor Switches Along With Two Ser...
Ameliorate the compensation of reactive power by using Static Synchronous Series Compensator
Power System Stability Problem Is An Occurrence Manifested As A Nonstandard Voltage, Current That Results In Disturbances Produced Which May Lead To Unwanted Or Unnecessary Effects On The Network, Such As Stability Disturbances, Voltage Flu...
Improvement of Power Flow and Voltage Stability using Unified Power Flow Controller
In This Paper We Are Discussing About A FACTs Device Named As UPFC (unified Power Flow Controller). Its Special Features Are To Control Active And Reactive Power Course In A Transmission Line And To Adjust The Voltage At The Bus At Which It...
FUZZY LOGIC CONTROL BASED ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS
An Active Power Filter Implemented With A Four-leg Voltage-source Inverter Using A Predictive Control Scheme Is Presented. The Use Of A Four-leg Voltage-source Inverter Allows The Compensation Of Current Harmonic Components, As Well As Unba...
Reactive Power Compensation using 12 MVA Capacitor Bank in 132/33 KV Distribution Substation
Shunt Capacitor Bank Improves The Power Factor, Increases Voltage Level On The Load And Reduces Current Flow Through The Transmission Lines. The Main Reason Of Installing A Capacitor Bank Is To Increase Power Factor Voltage Level. This Inap...
POWER QUALITY IMPROVEMENT IN INDUSTRIES USING HYBRID ACTIVE FILTER
This Paper Presents The Hybrid Active Power Filter (HAPF) For Harmonic Mitigation And Power Factor Improvement In A Non-linear Rectifier System. HAPF, Which Is Composed Of Passive Filter And An Active Filter In Series Connection, Operates A...
SIMULATION OF SERIES ACTIVE POWER FILTER FOR VOLTAGE HARMONICS COMPENSATION
The Two Major Problems In The Electrical Industry Today Are Sagging And Swelling Of Line Voltage And Harmonic Currents. Voltage Sagging And Swelling May Result To Equipment Malfunction And Shut Down. Harmonics Also Affect The Electrical...