Abstract |
In recent years, the introduction of Pre-Engineered Building (PEB) design of steel structures has helped in optimizing design concept with reducing the dead load of structure. The construction of PEB in the place of Conventional Steel Building (CSB) design concept resulted in many advantages as the members are design. The design of PEB structure as per bending moment distribution diagram over the whole span of beam and column and thus reducing the steel requirement with the help of using tapered IS- section. In this study an industrial structure PEB frame and Conventional steel frame is wind analysis and designed according to the Indian standards, IS 800-1984, IS 800-2007 and IS 875(part3):2015. The Conventional steel building and Pre-Engineered building calls for very fast construction of buildings and with good aesthetic looks and quality construction. Conventional steel building and Pre-Engineered building can be used extensively for construction of industrial and residential buildings. The present paper work was made in interest of studying various research work involved in analysis of PEB and conventional steel structure. |
Other Details |
Paper ID: IJSARTV Published in: Volume : 6, Issue : 11 Publication Date: 11/1/2020 |
Article Preview |
Download Article |